Environmental requirements
Table 4 shows the humidity and temperature limits for the IBM AnyPlace Kiosk.
Table 4. Environmental requirements
Temperature (dry
bulb)
Maximum
temperature (wet
bulb) Relative humidity
Operating
5 to 40°C
(41° to 104° F)
27° C
(81° F)
8to80%
Power disconnected
0 to 52°C ( 32° to 126°
F)
27° C
(81° F)
5to95%
Storage
0 to 60°C
(-32° to 140° F)
29° C
(84° F)
5to80%
Shipment
-40 to 60°C (-40° to
140° F)
29° C
(84° F)
5 to 100%
This product relies on active, convective cooling, so place your unit such that the
ambient air adjacent to the unit does not exceed supported maximums. Ensure that
the cooling vents are not blocked by papers, signs, or other items.
Power usage
Table 5 shows the power consumption for the IBM AnyPlace Kiosk:
Table 5. Power usage
Description Amounts
Power consumption Off: 3.4 W (11.6 BTU/hr)
Heat dissipation: Standby: 23.5 W (80.1 BTU/hr)
On (idle/typical): 66 W (225.2 BTU/hr)
On (maximum): 99 W (337.8 BTU/hr)
Input voltage and current 100–240 V, 50–60 Hz, 1.4 A max: Input to power supply
Calling for service
When you call IBM for warranty information or service, be sure to have the
following information available:
v Machine type/model
v Serial number
You can locate this information on the left side of the front bezel, or the rear side
of the unit.