EasyManuals Logo
Home>IBM>Server>SAN Volume Controller 2147-SV1

IBM SAN Volume Controller 2147-SV1 User Manual

IBM SAN Volume Controller 2147-SV1
194 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #134 background imageLoading...
Page #134 background image
Figure 109. Removed power supply
6. If you are instructed to return the power supply, follow all packaging instructions. Use any packaging
materials for shipping that are supplied to you.
Replace the power supply
7. To reinstall the PSU, or replace it with one from FRU stock, follow the procedure in “Installing or
replacing a power supply: 2145-92F ” on page 82.
Removing a drive: 2145-92F
You can remove a faulty drive from a 2145-92F expansion enclosure to replace it with a new one received
from FRU stock.
Before you begin
Ensure that the drive is not a spare or a member of an array. The drive status is shown in Pools > Internal
Storage in the management GUI. If the drive is a member of an array, follow the x procedures in the
management GUI. The x procedures minimize the risk of losing data or access to data; the procedures
also manage the system's use of the drive.
Important: You can remove a drive assembly without powering off the expansion enclosure. However, to
maintain operating temperature, complete the following tasks.
102
SAN Volume Controller : Model 2145-SV1 Hardware Installation Guide

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM SAN Volume Controller 2147-SV1 and is the answer not in the manual?

IBM SAN Volume Controller 2147-SV1 Specifications

General IconGeneral
BrandIBM
ModelSAN Volume Controller 2147-SV1
CategoryServer
LanguageEnglish

Related product manuals