Table 17. Power problems and actions (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v If an action step is preceded by “(Trained technician only),” that step must be performed only by a trained
technician.
v Go to the IBM support website at http://www.ibm.com/supportportal/ to check for technical information, hints,
tips, and new device drivers or to submit a request for information.
Symptom Action
Pwr rail 1 error has been
recorded in the system event
log.
1. Disconnect the server power cords.
2. (Trained technician only) remove microprocessor 1 if the Pwr rail 1 error has
been recorded in the system event log.
3. (Trained technician only) replace the system board (see “Removing the system
board” on page 260 and “Replacing the system board” on page 263).
4. Reinstall the component; then, restarting the server. If the Pwr rail 1 error has
been recorded in the system event log again, the component that you just
reinstalled is defective. Replace the defective component.
v (Trained technician only) Microprocessor 1 (see “Removing a microprocessor
and heat sink” on page 247 and “Replacing a microprocessor and heat sink”
on page 252).
Pwr rail 2 error has been
recorded in the system event
log.
1. Disconnect the server power cords.
2. (Trained technician only) remove microprocessor 2 if Pwr rail 2 error has been
recorded in the system event log.
3. Restart the server. If the Pwr rail 2 error has been recorded in the IMM event
log again, (trained technician only) replace the system board (see “Removing
the system board” on page 260 and “Replacing the system board” on page
263).
4. Reinstall the component; then, restarting the server. If the Pwr Rail 2 error has
been recorded in the system event log again, the component that you just
reinstalled is defective. Replace the defective component.
v (Trained technician only) Microprocessor 2 (see “Removing a microprocessor
and heat sink” on page 247 and “Replacing a microprocessor and heat sink”
on page 252).
Pwr rail 3 error has been
recorded in the system event
log.
1. Disconnect the server power cords.
2. Remove the following components if Pwr rail 3 error has been recorded in the
system event log:
v DIMMs 1 through 12
v Fan 3
v Fan 4
3. Restart the server. If the Pwr rail 3 error has been recorded in the system event
log again, (trained technician only) replace the system board (see “Removing
the system board” on page 260 and “Replacing the system board” on page
263).
4. Reinstall the components one at a time, in the order shown, restarting the
server each time. If the Pwr rail 3 error has been recorded in the system event
log again, the component that you just reinstalled is defective. Replace the
defective component.
v DIMMs 1 through 12 (see “Removing a memory module” on page 164 and
“Memory module installation” on page 165).
v Fan 3 (see “Removing a thermal kit (hot-swap fan)” on page 194 and
“Replacing a thermal kit (hot-swap fan)” on page 195).
v Fan 4
Chapter 3. Troubleshooting 95

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM System x3550 M5 Type 5463 and is the answer not in the manual?

IBM System x3550 M5 Type 5463 Specifications

General IconGeneral
Form Factor1U rack
Memory Slots24 DIMM slots
ProcessorIntel Xeon E5-2600 v3/v4 product family
MemoryUp to 1.5TB DDR4
StorageUp to 8x 2.5" HDD/SSD or 4x 3.5" HDD
RAID SupportRAID 0, 1, 10
Network InterfaceFour integrated Gigabit Ethernet ports (10/100/1000 Mbps)
Expansion SlotsUp to 3 PCIe 3.0 slots
Power SupplyDual redundant hot-swap 550W, 750W, or 900W
Operating Systems SupportedMicrosoft Windows Server, Red Hat Enterprise Linux, SUSE Linux Enterprise Server, VMware vSphere