9. Slide the server into the rack.
10. Reconnect the power cords and any cables that you removed.
11. Turn on the peripheral devices and the server.
Removing the DVD drive
Use this information to remove the DVD drive.
About this task
To remove a DVD drive, complete the following steps:
Note: The DVD drive is supported on the ten 2.5-inch hot-swap or simple-swap
hard disk drive model.
Procedure
1. Read the safety information that begins on “Safety” on page vii and
“Installation guidelines” on page 122.
2. Turn off the server and peripheral devices and disconnect all power cords.
3. Remove the server cover (see “Removing the cover” on page 126).
4. Press and hold the release tab down as you push the drive from the rear to
slide it out of the bay.
DVD drive
Release tab
Figure 67. DVD drive removal for 2.5-inch hard disk drive server models
Chapter 5. Removing and replacing components 153

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM System x3550 M5 Type 5463 and is the answer not in the manual?

IBM System x3550 M5 Type 5463 Specifications

General IconGeneral
Form Factor1U rack
Memory Slots24 DIMM slots
ProcessorIntel Xeon E5-2600 v3/v4 product family
MemoryUp to 1.5TB DDR4
StorageUp to 8x 2.5" HDD/SSD or 4x 3.5" HDD
RAID SupportRAID 0, 1, 10
Network InterfaceFour integrated Gigabit Ethernet ports (10/100/1000 Mbps)
Expansion SlotsUp to 3 PCIe 3.0 slots
Power SupplyDual redundant hot-swap 550W, 750W, or 900W
Operating Systems SupportedMicrosoft Windows Server, Red Hat Enterprise Linux, SUSE Linux Enterprise Server, VMware vSphere