Replacing a USB embedded hypervisor flash device
Use this information to replace a USB embedded hypervisor flash device.
About this task
To install a USB hypervisor flash device, complete the following steps:
Procedure
1. Read the safety information that begins on “Safety” on page vii and
“Installation guidelines” on page 122.
2. Turn off the server and peripheral devices and disconnect the power cords.
3. Remove the cover (see “Removing the cover” on page 126).
4. Align the flash device with the connector on the system board and push it into
the USB connector until it is firmly seated.
5. Reconnect the power cords and any cables that you removed.
6. Reinstall the cover (see “Replacing the cover” on page 127).
7. Slide the server into the rack.
8. Turn on the peripheral devices and the server.
USB embedded
hypervisor
flash device
Figure 134. USB hypervisor flash device installation
Chapter 5. Removing and replacing components 217