Table 17. Power problems and actions (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v If an action step is preceded by “(Trained technician only),” that step must be performed only by a trained
technician.
v Go to the IBM support website at http://www.ibm.com/supportportal/ to check for technical information, hints,
tips, and new device drivers or to submit a request for information.
Symptom Action
Pwr rail 6 error has been
recorded in the system event
log.
1. Disconnect the server power cords.
2. Remove the following components if the Pwr rail 6 error has been recorded in
the system event log:
v Optional cable for VGA external power
v PCI-E x8 and x16 (maximum expansion is 4 adapter cards)
v PCI-E hard disk drives
3. Restart the server. If the Pwr rail 6 error has been recorded in the system
event log again, (trained technician only) replace the system board (see
“Removing the system board” on page 260 and “Replacing the system board”
on page 263).
4. Reinstall the components one at a time, in the order shown, restarting the
server each time. If the Pwr Rail 6 error has been recorded in the system event
log again, the component that you just reinstalled is defective. Replace the
defective component.
v Optional cable for VGA external power
v PCI riser-card assembly (see “Removing a PCI riser-card assembly” on page
170 and “Replacing a PCI riser-card assembly” on page 172).
v Hard disk drives
Pwr rail 7 error has been
recorded in the system event
log.
1. Disconnect the server power cords.
2. Remove the following components if the Pwr rail 7 error has been recorded in
the system event log:
v Fan 1
v Fan 2
3. Restart the server. If the Pwr rail 6 error has been recorded in the system
event log again, (trained technician only) replace the system board (see
“Removing the system board” on page 260 and “Replacing the system board”
on page 263).
4. Reinstall the components one at a time, in the order shown, restarting the
server each time. If the Pwr Rail 6 error has been recorded in the system event
log again, the component that you just reinstalled is defective. Replace the
defective component.
v Fan 1 (see “Removing a thermal kit (hot-swap fan)” on page 194 and
“Replacing a thermal kit (hot-swap fan)” on page 195).
v Fan 2
Chapter 3. Troubleshooting 97

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM System x3550 M5 Type 5463 and is the answer not in the manual?

IBM System x3550 M5 Type 5463 Specifications

General IconGeneral
BrandIBM
ModelSystem x3550 M5 Type 5463
CategoryServer
LanguageEnglish

Related product manuals