I.58015 [I.58015]
Explanation: Memory spare copy initiated. Spare Copy Started
Severity: Info
User response: Complete the following steps:
1. Information only; no action is required.
I.580A4 [I.580A4]
Explanation: Memory population change detected. DIMM Population Change Detected
Severity: Info
User response: Complete the following steps:
1. If you have added or removed DIMMs to the system, and no additional errors were detected, then please ignore
this message.
2. Check system event log for uncorrected DIMM failures and replace those DIMMs.
I.580A5 [I.580A5]
Explanation: Mirror Fail-over complete. DIMM number % has failed over to to the mirrored copy. DIMM Mirror
Fail-over Detected
Severity: Info
User response: Complete the following steps:
1. Check the system-event log for uncorrected DIMM failures and replace those DIMMs.
I.580A6 [I.580A6]
Explanation: Memory spare copy has completed successfully. Spare Copy Complete
Severity: Info
User response: Complete the following steps:
1. If you have added or removed DIMMs to the system, and no additional errors were detected, then please ignore
this message.
2. Check system event log for uncorrected DIMM failures and replace those DIMMs.
S.1100B [S.1100B]
Explanation: CATERR(IERR) has asserted on processor %. Processor CATERR(IERR) has asserted
Severity: Error
User response: Complete the following steps:
1. Check IBM support site for an applicable service bulletin or UEFI firmware update that applies to this Processor
error.
2. (Trained service technician only) If there are multiple Processor’s, swap Processor’s to move affected Processor to
another Processor socket and retry. If problem follows the affected Processor, or this is a single Processor system,
replace the Processor.
3. (Trained Service technician only) Inspect Processor socket on each Processor removal and replace system board
first if damaged or mis-aligned pins are found. Replace the system board.
I.58015 S.1100B
Appendix B. UEFI/POST diagnostic codes 671

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM System x3550 M5 Type 5463 and is the answer not in the manual?

IBM System x3550 M5 Type 5463 Specifications

General IconGeneral
Form Factor1U rack
Memory Slots24 DIMM slots
ProcessorIntel Xeon E5-2600 v3/v4 product family
MemoryUp to 1.5TB DDR4
StorageUp to 8x 2.5" HDD/SSD or 4x 3.5" HDD
RAID SupportRAID 0, 1, 10
Network InterfaceFour integrated Gigabit Ethernet ports (10/100/1000 Mbps)
Expansion SlotsUp to 3 PCIe 3.0 slots
Power SupplyDual redundant hot-swap 550W, 750W, or 900W
Operating Systems SupportedMicrosoft Windows Server, Red Hat Enterprise Linux, SUSE Linux Enterprise Server, VMware vSphere