166-810-001 IMM I2C Test Aborted
Explanation: Request data length invalid.
Severity: Warning
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Perform the actions mentioned one at a time and try the test after each action:
1. Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power.
2. Make sure that DSA and BMC/IMM are at the latest level.
Related Links:
v IBM Support Website
v Latest level of DSA
v Latest level of BMC/IMM
166-811-001 IMM I2C Test Aborted
Explanation: Request data field length limit exceeded.
Severity: Warning
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Perform the actions mentioned one at a time and try the test after each action:
1. Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power.
2. Make sure that DSA and BMC/IMM are at the latest level.
Related Links:
v IBM Support Website
v Latest level of DSA
v Latest level of BMC/IMM
166-812-001 IMM I2C Test Aborted
Explanation: Parameter out of range.
Severity: Warning
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Perform the actions mentioned one at a time and try the test after each action:
1. Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power.
2. Make sure that DSA and BMC/IMM are at the latest level.
Related Links:
v IBM Support Website
v Latest level of DSA
v Latest level of BMC/IMM
166-810-001 • 166-812-001
Appendix C. DSA diagnostic test results 809