64
HDK-99 1803 VER1 (E)
4.5 Output Signal Check
Test Pulse (CAL Signal) Check
Check if the level of the video system is normal.
1 Set the CAL button on the OCP or MCP to ON.
Ensure that 100% level of test pulse is output.
2
WFM/PM
SEQ
Super
−G
R
G B
Y
ENC
100%
80%
60%
40%
20%
0%
-20%
MCP
OCP
"R", "G", "B", "Y", "SEQ"
WFM/PM (Setup 1/2) button
PM
WFM
(SEQ: R, G, B)
MONITOR SELECT
button
"R", "G", "B", "Y",
"SEQ"
CAL button "ON"
External Chart Check
Shoot an external chart and ensure that the image is normal.