SD1 Series Inverters Product Overview
-9-
Function
Specification
EMI filter
3PH 400V 4kW and above/3PH 230V 1.5kW and
above can comply with IEC 61800-
3 class C3,
others can meet requirements of IEC 61800-
3 class
C3 by installing external filter (optional). This series
of products can comply with IEC 61800-
3 class C2
by installing external filter (optional).
Ambient temperature
-10 to 50°C, derate 1% for every increased 1°C
when the temperature is higher than 40°C
Altitude
Below 1000m. If the elevation is above 1000m,
derate 1% for every additional 100m.
Ingress protection (IP)
rating
IP20
Note: The inverter with
plastic casing should be
installed in metal distribution cabinet which
conforms to IP20 and the top of which conforms to
IP3X.
Pollution level
Level 2
Safety regulation
Comply with CE requirements
Cooling mode
Forced air cooling