Installation and programming manual
Options and programming methods 79
Event code
This is the 2-character alphanumeric code, which corresponds to the event sent the alarm
receiving centre (ARC). For zone and terminal events (alarm, tamper, bypass), the “CCC”
field of the CONTACT-ID protocol counts the number of hard terminals in accordance with
the Hard terminals table (refer to Appendix E, Screw Terminals).
Outputs
When programming the Event-Activation section, you must programme the main output
which will be activated when the event occurs. When programming the Event-Restoral
section, you must programme the main output which will be activated when the event ends.
Select the output from the list (which includes the Relay outputs, OC1, OC2 and the
terminals configured as outputs and also the sounderflashers) and press .
Note
If the output has the “ON afterRestoral” option enabled (refer to paragraph 7-8 Outputs) and it is
programmed on event restoral, the output will deactivate when the event occurs.
For Zone alarm, Terminal tamper, Partition alarm, Stay partition alarm and Partition
tamper events, monostable outputs programmed in the “Outputs” section will restore
these events when, on expiry of the monostable time, the event concerned has
effectively returned to standby status. If the event status restores to standby while the
monostable time is running, the event itself will not be restored.
Other outputs
This section allows activation of added outputs (as well as the output programmed in
the “Outputs” parameter) when the event occurs or restores.
These added outputs can be selected by means of keys and from a
programmable list in the “Added Outputs” section.
OtherOutputsProg
This section allows the creation of the list of outputs (16 for “Activation” or 8 for
“Restoral” to be programmed in the “Other outputs” section.
Note
This is the sole list for the entire control panel and is independent of the type of event.
Use keys and to make your selection and then press to confirm.
SIA Codes
If the event is associated with calls using SIA or SIA-IP protocol, this option allows you to
programme the event code in accordance with SIA Standard, by selecting it from a list.
Use keys and to make your selection and then press to confirm.
An appendix provides an explicative table of all the SIA codes (Appendix G, SIA Codes).
Siren sound types
This section allows you to select the audible-visual signals emitted by the
sounderflashers, when these are programmed in the “Outputs” and “Other outputs”
section.
Please note that the “Tone Type” is a parameter of the event. Therefore, if several
sounderflashers have been programmed in relation to a specific event, they will all emit
the programmed tone when the event occurs. If a sounderflasher has been
programmed in relation to several events, it will emit the last tone type setting received
in order of time.
Use keys and to make your selection and then press to confirm.
For further information regarding the “Outputs”, “Other outputs” and “Tone type” parameters
of each event, refer to Appendix F, Combination of outputs triggered by events.
Via PC
Table 7-9:
Events - via SmartLeague
Option Part of the system Template/section
TelephoneNumbers
SmartLiving System - Events - select a single event
Programming
Message type
Message A
Message B
Options
Class code
Event code
Outputs
Other outputs
Parameters settings - Other outputs