Intel
®
Omni-Path Fabric Switches
May 2016 Installation Guide
Doc. No.: H76456Rev 3.0US 61
Omni-Path Switches
2. Get to a [boot]: prompt by following either Step a or b.
a. If the management module is running and displays the -> prompt, type the
following command at the console:
reboot now
and press ENTER.
b. If the module is not running, power on the switch.
3. When the system displays
image1 or image2, press the SPACEBAR to interrupt
the auto load sequence before the counter expires (within 5 seconds).
4. At the
[boot]: prompt type the following:
moduleip <NEW IP ADDRESS>
and press ENTER.
Note: The
moduleip command changes the IP address for image1 and image2 on each
module.
5. At the
[boot]: prompt type reboot, and press ENTER. Following the reboot, the
IP address is changed. Repeat these steps for the second management module.