Chapter 3 — Develop and Use RFID Applications
IF2 Network Reader User Manual 43
2 Specify the value (in ms) for the antenna or ID timeout in the
entry fields and then click Activate Changes.
For more information on ID Timeout and Antenna Timeout, see
those topics later in this section.
Select Tries
(Not supported by EPCglobal Class 1 Gen 2 tags) Sets the number of
times a group select is attempted. A group select is the command that
starts the identity process. Valid range is 1 (default) to 254.
This setting is equivalent to the SELTRIES BRI attribute.
Unselect Tries
(Not supported by EPCglobal Class 1 Gen 2 tags) Sets the number of
times a group unselect is attempted. Valid range is 1 (default) to 254.
Session
(EPCglobal Class 1 Gen 2 tags only) Sets the command session
parameter to the corresponding EPCglobal Class 1 Gen 2 air protocol
command (default is QueryAdjust).
This setting is equivalent to the SESSION BRI attribute. For more
information on this setting, see the EPCglobal Class 1 Gen 2
documentation.
Initial Q
(EPCglobal Class 1 Gen 2 tags only) Sets the initial Q parameter value
used by the Query command. Valid range is 0 to 15 (default is 4). If
you know there is only one tag in the field, set this attribute to 0 for
best performance.
This setting is equivalent to the INITIALQ BRI attribute.
Initialization Tries
Sets the maximum number of times the reader attempts to initialize a
tag. Valid range is 1 (default) to 254.
This setting is equivalent to the INITTRIES BRI attribute.