Chapter 3 — Develop and Use RFID Applications
46 IF2 Network Reader User Manual
2 Change BRI server settings as needed. For help, see the next table.
3 Click Activate Changes to save your changes and immediately
make them active.
View the BRI Server Log
If you enable logging, you can see a list of BRI server events. You can
save the logfile as a .txt file.
To enable BRI server logging and view the logfile
1 Enable BRI logging as described in the previous section,
“Configure the BRI Server” on page 45.
BRI Server Parameter Descriptions
Parameter Description
Enable External
BRI Connections
Enables/disables external TCP connections to the BRI
server. If this check box is not checked, BRI applications
will not be able to connect to the IF2.
BRI TCP Port Specifies the TCP port used for incoming connections
to the BRI server. This port must be unique for all TCP
services running on the IF2. Valid range is 2189 to
65535. Default is 2189.
Enable Logging Enables/disables logging of BRI server events.
For more information on logging, see the next section.
Enable BRI on
serial port
Enables/disables sending BRI commands through the
serial port.