Chapter 4 — Configuration Command Reference
58 SR61T Tethered Scanner User’s Guide
Turn Off After Good Read
Sets how the SR61T operates in level and pulse trigger modes.
Vibrate Alert
Enables or disables the vibrate alert. When Vibrate Alert is enabled,
the scanner vibrates when you scan a valid bar code.
Vibrate Alert Duration
Sets the amount of time that the vibrate alert remains on. You can set
Vibrate Alert Duration to a value from 0 to 2550 ms.
Turn Off After Good Read Options
Trigger Mode
Turn Off After
Good Read
SR61T Behavior
Level Enabled The SR61T scanner beam turns off after
it successfully reads a bar code.
Level Disabled The SR61T scanner beam stays on until
you release the Scan button.
Pulse Enabled The SR61T scanner beam turns off after
it successfully reads a bar code.
Pulse Disabled The SR61T scanner beam stays on until
the Trigger Timeout period is reached.