EasyManua.ls Logo

INVT Goodrive350 IP55

INVT Goodrive350 IP55
372 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Goodrive350 IP55 High-ingress Protection Series VFD Function parameter list
-224-
Function
code
Name
Description
Default
value
Modify
P24.10
Initial angle of
the pole
Relative electric angle of encoder position and
motor pole position.
Setting range: 0.00359.99
0.00
P24.11
Autotuning of
initial angle of
pole
03
1: Rotary autotuning (DC brake)
2: Static autotuning (suitable for resolver-type
encoder, sin/cos with CD signal feedback)
3: Rotary autotuning (initial angle identification)
0
P24.12
Speed
measurement
optimization
selection
0: No optimization
1: Optimization mode 1
2: Optimization mode 2
1
P24.13
CD signal zero
offset gain
065535
0
P24.14
Encoder type
selection
0x000x11
Ones: Incremental encoder
0: without UVW
1: with UVW
Tens: Sin/Cos encoder
0: without CD signal
1: with CD signal
0x00
P24.15
Speed
measurement
mode
0: PG card
1: local; realized by HDIA and HDIB; supports
incremental 24V encoder only
0
P24.16
Frequency-
division
coefficient
0255
0
P24.17
Pulse filer
processing
0x00000xFFFF
Bit0: Enable/disable encoder input filter
0: No filter
1: Filter
Bit1: Encoder signal filter mode (set Bit0 or Bit2
to 1)
0: Self-adaptive filter
1: Use P24.18 filter parameters
Bit2: Enable/disable encoder frequency-division
output filter
0: No filter
1: Filter
Bit3: Reserved
Bit4: Enable/disable pulse reference filter
0: No filter
1: Filter
Bit5: Pulse reference filter mode (valid when
Bit4 is set to 1)
0: Self-adaptive filter
1: Use P24.19 filter parameters
Bit615: Reserved
0x0033