Goodrive350 IP55 High-ingress Protection Series VFD Basic Operation Instructions
-71-
3. Logic diagram for restart after automatic fault reset
VFD fault
In running
Automatic reset times
of VFD fault<P08.28
Automatic reset
interval of VFD
fault>P08.29
VFD fault reset,
start running
Display fault
code, and stop
N
N
Y
Y
Related parameter list:
0: Keypad
1: Terminal
2: Communication
0: Direct start
1: Start after DC brake
2: Start after speed-track
Starting frequency of direct
start
Hold time of starting
frequency
DC brake current before start
DC brake time before start
Acceleration/deceleration
mode
0: Straight line
1: S curve
Note: If mode 1 is selected, it is required to
set P01.07, P01.27 and P01.08
accordingly
0: Decelerate to stop
1: Coast to stop
Starting frequency of DC
brake after stop
0.00Hz–P00.03 (max. output frequency)