EasyManua.ls Logo

ISCO 6700SR - Page 45

ISCO 6700SR
190 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6700SR Refrigerated Sampler
27
Example 5 Standard Program: Flow-Paced Sampling, Two
Bottles Per Sample
• Program type: Standard
• Site description: SITE 29
• Units for Length: Feet
• Data Storage Interval: 15 minutes
• Bottle kit: 24, 1000 milliliter bottles
• Suction line length: 7 feet
• Pacing: Flow pacing, every two pulses
• Distribution: 2 bottles per sample
• Sample Volume: 250 milliliters
• Start time: Clock Time, 6:00 a.m. on Monday, Wednesday, Fri-
day
• Module
:
No module installed
1
6700 SAMPLER
STANDARD PROGRAMMING
For HELP at any
screen press ? key.
2
RUN
PROGRAM
VIEW REPORT
OTHER FUNCTIONS
Select PROGRAM.
3
SITE DESCRIPTION
“SITE 29 “
CHANGE
YES
NO
Select NO.
(The margin example, Using the Site Description or Program Name Menus
on page 18, shows you how to change the site description.)
4
SELECT UNITS FOR
LENGTH
ft
m
Select ft.
5
DATA STORAGE
INTERVAL IN MINUTES
1 2 5
10
15
30
Select 15.
6
NUMBER OF BOTTLES
124812
24
Select 24.
7
BOTTLE VOLUME IS
1000
ml (300-30000)
Enter 1000.
8
SUCTION LINE LENGTH
IS
7
ft
(3-99)
Enter 7.
9
TIME PACED
FLOW PACED
Select FLOW PACED.

Table of Contents