EasyManua.ls Logo

Iseki SGR19 - Re-Assembly

Iseki SGR19
128 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
116
SERVICE MANUAL FOR SGR19 & SGR17
j. Inspection of the IC regulator
Fig. 9-59
6.5. RE-ASSEMBLY
Re-assemble in reverse order of disassembly,
following the next precautions.
a. Pressing in the bearings
Press in the bearing with a hand press carefully
to avoid slanted installation.
At room temperature, it is very hard to press in
the bearing due to interference. So it is recom-
mendable to heat up the whole frame at about
100°C.
Note:
When installing the bearing, use a jig which is
designed to press only the outer race. Support
the frame at the bearing box not at the stay.
Fig. 9-58
• Connect the removed IC regulator, variable DC
power supply, voltmeter, and a lamp as illus-
trated. (Keep SW1 and SW2 turned off.)
• Set the power supply at 12V.
• Turn on SW1. Make sure that L1 (in place of the
charge lamp) is lit bright and L2 (in place of the
rotor coil) is also lit.
• Then turn on SW2 with SW1 on. Make sure that
L1 is turned off and L2 remains lit.
• When the power supply output is changed gradu-
ally from 12V until 14.5±0.6 at about 25°C with
both SW1 and SW2 turned on, L2 should turn
off and L1 should remain turned off.
After above test, check the diode between ter-
minal B and F.
• Set the tester at KΩ range and check for conti-
nuity across terminals B and F. Check by chang-
ing the polarity of the tester. There should be
continuity in one direction and no continuity in
the other direction.

Table of Contents