Output Commands
Copyright© Itech Electronics Co., Ltd. 31
Unit
S
Reset Value
0.001
Example
CURR:RISE 10.0
Query syntax
[SOURce:]CURRent:RISE[:LEVel]? [MINimum|MAXimum]
Returns
NRf
[SOURce:]CURRent:FALL[:LEVel]
This command is used to set falling time of current.
Command syntax
[SOURce:]CURRent:FALL[:LEVel] <MINimum|MAXimum|NRf>
Arguments
MINimum|MAXimum|NRf
Unit
S
Reset Value
0.001
Example
CURR:FALL 2.0
Query syntax
[SOURce:]CURRent:FALL[:LEVel]? [MINimum|MAXimum]
Returns
NRf
[SOURce:]CURRent:PROTection:STATe
This command is used to set over current protection state.
Command syntax
[SOURce:]CURRent:PROTection:STATe <bool>