Query syntax
LOAD:CURRent[:LEVel][:IMMediate][:AMPLitude]? [MINimum|MAXimum]
Returns
NRf
LOAD:CURRent:MINimum[:LEVel]
This command is used to set minimum value of load current.
Command syntax
LOAD:CURRent:MINimum[:LEVel] <MINimum|MAXimum|NRf>
Arguments
MINimum|MAXimum|NRf
Unit
A
Reset Value
0.0
Example
LOAD:CURR:MIN 2.0
Query syntax
LOAD:CURRent:MINimum[:LEVel]? [MINimum|MAXimum]
Returns
NRf
Related Command
LOAD:CURR:MAX,LOAD:CURR
LOAD:CURRent:MAXimum[:LEVel]
This command is used to set maximum value of load current.
Command syntax
LOAD:CURRent:MAXimum[:LEVel] <MINimum|MAXimum|NRf>
Arguments
MINimum|MAXimum|NRf