Car Wave CommandIT6500C
Copyright© Itech Electronics Co., Ltd. 77
Returns
<CRD>
CARWave:ISO16750:LOAD:DUMP[:VOLTage]:UN[:LEV
el]
This command is used to set peak voltage of load dump wave of car.
Command syntax
CARWave:ISO16750:LOAD:DUMP:UN <value>
Arguments
MINimum|MAXimum|NR3
Reset Value
MINimum
Example
CARW:ISO16750:LOAD:DUMP:UN 50
Query syntax
CARW:ISO16750:LOAD:DUMP:UN? [MINimum|MAXimum]
Returns
NR3
CARWave:ISO16750:LOAD:DUMP[:VOLTage]:US[:LEV
el]
This command is used to set the clamp voltage of load dump wave of car.
Command syntax
CARWave:ISO16750:LOAD:DUMP:US <value>
Arguments
MINimum|MAXimum|NR3
Reset Value
MINimum
Example
CARW:ISO16750:LOAD:DUMP:US 40
Query syntax
CARW:ISO16750:LOAD:DUMP:US? [MINimum|MAXimum]