Wave Operation Command
Copyright© Itech Electronics Co., Ltd. 67
Query syntax
SEQuence[:STEP]:CURRent? <NR1>,[MINimum|MAXimum]
Returns
NRf
SEQuence[:STEP]:LOAD:CURRent?
This command is used to edit the load current of specified step of a
sequence file. This command is prepared for IT6500C model.
Arguments
<NR1>,MINimum|MAXimum|NRf
Unit
s
Example
SEQ:LOAD:CURR 1,0.5
Query syntax
SEQuence[:STEP]:LOAD:CURRent? <NR1>
Returns
<NRf>
SEQuence[:STEP]:WIDTh
This command is used to edit the width of specified step of the wavefile .
Command syntax
SEQuence[:STEP]:WIDth <NR1>,<MINimum|MAXimum|NRf>
Arguments
<1~10>,MINimum|MAXimum|NRf
Unit
s
Example
SEQ:WIDT 1,64
Query syntax
SEQuence[:STEP]:WIDTh? <NR1>,[MINimum|MAXimum]
Returns
NRf