EasyManuals Logo
Home>ITech>Power Supply>IT6500C Series

ITech IT6500C Series Manual

ITech IT6500C Series
126 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #68 background imageLoading...
Page #68 background image
Load Related CommandIT6500C
Copyright© Itech Electronics Co., Ltd. 57
Command syntax
LOAD:POWer:MAXimum[:LEVel] < MINimum|MAXimum|NRf>
Arguments
MINimum|MAXimum|NRf
Unit
W
Reset Value
MAXimum
Example
LOAD:POW:MAX 3100
Query syntax
LOAD:POWer:MAXimum[:LEVel]? [MINimum|MAXimum]
Returns
NRf
Related Command
LOAD:POW:MIN,LOAD:POW
LOAD: POWer:RISE[:LEVel]
This command is used to set rising time for load power.
Command syntax
LOAD:POWer:RISE[:LEVel] <MINimum|MAXimum|NRf>
Arguments
MINimum|MAXimum|NRf
Unit
S
Reset Value
0.001
Example
LOAD:POWer:RISE[:LEVel] 200ms
Query syntax
LOAD:POWer:RISE[:LEVel]? [MINimum|MAXimum]

Table of Contents