Command syntax
CARWave:ISO16750:STARtup:PROFile:INDex <1|2|3|4>
Arguments
1|2|3|412V, 1|2|324V
Reset Value
1
Example
CARW:ISO16750:star:prof:ind 1
Query syntax
CARWave:ISO16750:STARtup:PROFile:INDex?
Returns
<CRD>
CARWave:STARtup:DIN40839[:STATe]
This command is used to analog DIN40839 startup wave of car.
Command syntax
CARWave:STARtup:DIN40839 <bool>
Arguments
0|1|OFF|ON
Reset Value
0
Example
CARW:STAR:DIN40839 1
Query syntax
CARWave:STARtup:DIN40839?
Returns
0|1
CARWave:STARtup:DIN40839:VOLTage[:SELect]
This command is used to select DIN40839 startup wave voltage of car.
Command syntax
CARWave:STARtup:DIN40839:VOLTage <12V|24V>