Output Commands
Copyright© Itech Electronics Co., Ltd. 44
Arguments
VOLTage|RESistance
Reset Value
VOLTage
Example
EXT:PROG:MODE VOLT
Query syntax
[SOURce:]EXTern:PROGram:MODE?
Returns
VOLTage|RESistance
[SOURce:]EXTern:PROGram:RANGe
This command is used to set external program range.
Command syntax
[SOURce:]EXTern:PROGram:RANGe <10V/10K|5V/5K>
Arguments
10V/10K|5V/5K
Reset Value
10V/10K
Example
EXT:PROG:RANG 10V/10K
Query syntax
[SOURce:]EXTern:PROGram:RANGe?
Returns
[SOURce:]EXTern:PROGram:RANGe?
[SOURce:]OUTPut[:STATe]
This command is used to control the output switch state.
Command syntax
[SOURce:]OUTPut[:STATe] <bool>
Arguments
0|1|OFF|ON