Page #72 background image
List Operation Commands
Copyright© Itech Electronics Co., Ltd. 61
Chapter10 List Operation Commands
LIST[:STATe]
This command is used to set the state of list mode. If the state is ON ( 1 ),
and the list file can not be edit.
Command syntax
LIST[:STATe ]<bool>
Arguments
0|1|OFF|ON
Reset Value
0
Example
LIST:STAT 1
Query syntax
LIST:STATe?
Returns
0|1
LIST:RECall
This command is used to recall a list file.
Command syntax
LIST:RECall <MINimum|MAXimum|<1~10>>
Arguments
MINimum|MAXimum|<1~10>
Example
LIST:REC 1
Query syntax
LIST:RECAll?
Returns
NR1