DVR Integration Option Protocol Integration
24-10515-13 Rev. – 4-15
This document contains confidential and proprietary information of Johnson Controls, Inc.
© 2010 Johnson Controls, Inc.
The value of Preset Number in the Nextiva configuration should match the preset
number used in the OPC Name of the P2000 configuration (see page 2-20).
The following screen shows the Add Preset window
in the Nextiva Review
software.
When configuring Nextiva AV Switch in the P2000 server, the Streaming Server IP
Address, Data Server IP Address, and Storage Server IP Address must all be set
to the Nextiva IP address (see “Audio-Visual Tab for Protocols Other Than
SmartSight” on page 2-10).
After making changes to the Nextiva configuration, stop and restart the AV Service
and the CCTV Server using P2000 Service Control in the P2000.