JS-MD 3 RES Maintenance Manual
Supplement
MD11-AMM-00-002
Issue: 00
Rev. 00
Rev. Date: 23-May-22
Page A-3
JS-MD 3
ANNUAL (OR 100 HOUR MOTOR OPERATION)
INSPECTION CHECKLIST
SIGN
action completed
SIGN checked
Inspect fan bolts
Clean fans and fan finger guards
Inspect wiring loom for damage on both sides where it passes through the
fan plate
Air cooled controller (if fitted)
Inspect all Controller box fastening bolts
Inspect high voltage cables for damage where they pass through the box
Inspect Motor controller data connectors for damage
Liquid cooled controller (if fitted)
Inspect all Controller box fastening bolts
Inspect high voltage cables for damage where they pass through the box.
Inspect Motor controller data connectors for damage
Inspect piping and radiator for water leakages.
Inspect security of radiator, fan and water pump assembly
Inspect coolant level (section 4.11.2.4.5)
RFU- IMD assembly
Inspect connectors to RFU and IMD for damage

Table of Contents