JD-1307-05 Attachment 1 5/11
62
62
73
73
10
(GND)
65432211
NCU-331/NCU-692 terminal block
NQD-4190 Junction Box
Terminal number
7
61
61
60
60
59
59
58
58
57
57
56
56
55
55
6
6
RBK2
MPYCYS-12
"RBK2" wire
(7ZCJD0258 attached)
Solder the "RBK2" wire to
unusing wire and insulate it
with vinyl tape.
To NQD-4190
NCU-331/692
Terminal connection
6. Remove the front panel of NCU-331/692.
Unscrew 4 screws.
7. Connect “RBK2” wire to NCU-331/692 terminal block No.6.
8. Return the front panel of NCU-331/692.
9. Return the upper cover of NQD-4190.
10. Return the upper cover of NFC-296.
Note
(a) Confirm connections of cables and connector before
returning the upper cover.
(b) Screw the upper cover in order of figure.
(The standard of tightening torque is 15 kgfcm.)
11. Return the shade cover and earth wire.
Replacing the CFG-296 Matching Unit in the NFC-296 is finished.