(f)  Press ENT and turn the dial to “ORDINARY” voltage on the LCD.   
 
CHG VOLT ADJUST 
ORDINARY 26.2V 
 
(g) Adjust the Floating Charge Voltage by RV1. 
(h) Turn the dial to “EQUAL” voltage on the LCD and adjust the Equal Charge Voltage by RV2.   
 
CHG VOLT ADJUST 
EQUAL  29.4V 
 
(i)  Press ENT and turn off the “AC” switch. 
(j)  Re-assemble the unit. 
 
4.2.3  Battery operation setting 
If the Power Generator for emergencies is not equipped, set the battery using setting to SINGLE 
(SES/HF) by the “BATT USE SET” menu. 
 
Procedure
(a) Turn on the “AC” switch, pressing MENU . 
(b) Press MENU and turn the dial to “BATT USE SET” menu on the LCD. 
(c) Press ENT and set with the dial “DUAL (SES, HF)” or “SINGLE (SES/HF)” on the LCD. 
 
BATT USE SET 
 SINGLE (SES/HF) 
 
  DUAL (SES, HF):  The Power Generator for emergencies is equipped in ship. 
SES and HF can be use simultaneously. 
The Battery operation time is 1 hour or more. 
SINGLE (SES/HF):  The Power Generator for emergencies is not equipped in ship. 
SES and HF can’t be use simultaneously. 
The Battery operation time is 6 hours or more. 
(d) Press ENT and turn off the “AC” switch. 
 
 
4.2.4  PA Vc (78V) setting   
 
Since PA Vc (78V) is already adjusted at the time of factory shipments, it is not necessary to 
adjust it at the time of installation. 
 
Procedure
 
Note 
(a) Turn off the “AC” and “DC” switches on the front panel. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
CBG-2692
PS UNIT
80V ADJ
RV3
AC switchDial
80V -
80V +
TB19
TB20
78.0v
Digital Volt
Meter
+-
48