EasyManua.ls Logo

JRC JSS-296 - Connection of NCH-321 A Distress Message Controller

JRC JSS-296
220 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3.7 Connection of NCH-321A Distress Message Controller
Connect the NCH-321A Distress Message Controller according to the serial number of NCT-196N as
follows.
NCT-196N numbered GA13417 or later.
NCT-196N
DMC TERMINAL
DMC_DAL
DMC_DRQ
DMC_DRA
DMC_SEL
DMC_RDY
GND
+12V
1
2
3
4
5
6
7
8
9
10
67
68
69
70
71
72
73
NCU-324/331
GMDSS CONSOLE
27
22
26
21
25
23
24
NCH-321A
DMC
DAL
DRQ
DRA
SEL
RDY
GND
+9V
SP_OUT
DC_OUT
DEM_OUT
NCT-196N numbered from GA13195 to GA13244 and from GA13355 to GA13417.
NCT-196N
DMC TERMINAL
DMC_DAL
DMC_DRQ
DMC_DRA
DMC_SEL
DMC_RDY
GND
+12V
1
2
3
4
5
6
7
8
9
10
67
68
69
70
71
72
73
NCU-324/331
GMDSS CONSOLE
27
22
26
21
25
23
24
NCH-321A
DMC
DAL
DRQ
DRA
SEL
RDY
GND
+9V
SP_OUT
DC_OUT
DEM_OUT
45