4.7.5 Max power setting
Max TX power can be setting in the menu.
ATTENTION
If the Max power setting is changed, the BAND power setting is cleared.
This menu cannot be selected when a power setting by the menu 2 is LOW.
Procedure
TX FREQ
RX FREQ
MAXPOWER
4,500.
0
kHz
AGC
4,20
0
.0
kHz
2
9
RDY
(a) Select the MENU number 29 by the jog dial
or keypad.
ENT
Turn the
j
o
g
dial
MENU
or
2
ENT
MENU
9
(b) Select “AC” or “DC” by the jog dial and
press .
TX FREQ
RX FREQ
MAXPOWER
4,500.0 kHz
AGC
4,200.0 kHz
AC
RDY
ENT
(c)
Select TX power by the jog dial and
press .
TX FREQ
RX FREQ
MAXPOWER
HF 500 kHz
AGC
MF 400 kHz
6
ENT
Refer to the following TX power tables.
RDY
DC TX power table
JSS-296/596/896
(JSB-196GM)
50 75 100 125* 150*
(*) TX power of MF band is 100W.
AC TX power table
Equipment 1 2 3 4 5 6
MF 50 75 100 150 150 200
JSS-296
HF 50 75 150 150 250 250
MF 50 75 150 200 250 400
JSS-596
HF 50 75 150 250 400 500
MF 50 75 150 200 250 400
JSS-896
HF 50 75 250 500 800 800
(d) Press to exit the menu.
MENU
70