- 5 -
24V(+)
24V(+)
BATT
Connect to the DC
Terminal No.3-No.6
OFF
ON
24V(+)
24V(+)
BATT
Connect to the DC
Terminal No.3-No.6
Circuit Tester
(14) Connect the Breaker Cable and the BATT Cable to the breaker with four
M5X8-screws contained in the Breaker Addition Kit.
(15) Check the Breaker connection as the following table shows.
Breaker
Between 24V(+)
terminals
Between 24V(-)
terminals
ON Short Short
OFF Open Open
Note: Turn off the breaker after checking.