Each parameter is set as follows:
ARQ/FEC 4- or 5-digit Self-ID : Press Enter and setup ID number.
GFEC 4- or 5-digit Self-ID : Press Enter and setup ID number.
ARQ/FEC 9-digit Self-ID : Press Enter and setup ID number.
GFEC 9-digit Self-ID : Press Enter and setup ID number.
Answerback : Press Enter and setup answerback.
Max. FEC error rate : Press Enter and setup in the input display.
Max. automatic call series : Press Enter and set a value of 1-99 in the input display.
Collective FEC receiving : Press Enter toggles the setting between ON and OFF.
Internal alarm : Press Enter toggles the setting between ON and OFF.
Time duration for AUTO/MRTX : Press Enter and set up the time in the input display.
Restart : Press Enter toggles the setting between ON and OFF.
Finite start/restart : Press Enter toggles the setting between ON and OFF.
Transmitter pre-key time : Press Enter and set up in the input display.
After these settings are finished, select one of the following options to complete the setup.
Save : Saves these settings.
Cancel : The initial display returns without saving.
The meanings of the above items are as follows;
Note
・Max. FEC error rate : The limit value of error rate to continue to receive CFEC/
SFEC. When the error rate is beyond the value due to the noisy
radio circuit condition or any other signals, the MODEM stops
the receiving and return to stand-by.
・Max. automatic call series : The limit value of retrying the CALL mode sequence. The
interval to retry is 15 minutes respectively.
・Collective FEC receiving : ON - CFEC receiving is permitted.
OFF - CFEC receiving is prohibited.
・Internal alarm : ON - Internal alarm works.
OFF - Internal alarm does not work.
・Time duration for AUTO : Time duration setting for AUTO mode
・Restart : ON - The MODEM tries to reconnect when the circuit
established once is lost for 32 times of successive
REPEAT condition
OFF - The MODEM returns to stand-by when the circuit
established once is lost for 32 times of successive
REPEAT condition
・ Finite start/restart : ON - The MODEM returns to stand-by when the times of
calling a partner station are reached to 128 in ARQ
mode.
OFF - The MODEM continues to call a partner station even if
the times of calling are reached to 128 in ARQ mode.
・Transmitter pre-key time : Adjustment of timing from KEY ON to signal output for the
transmitter electrical specification. It is also available to arrange the
Send/Receive timing between long-ranged partner station.