Table 26: EX2200 Switch Mounting Methods (continued)
CommentsSwitch ModelMounting Method
•
On a wall by using screws or separately orderable wall-mount
kit
•
On a wall by using screws
•
EX2200
•
EX2200-C
Wall mount
On or under a surface made of ferrous material using the separately
orderable magnet sheet
EX2200-CMagnet mount
WARNING:
When mounting an EX2200 switch chassis in a vertical position, orient the
front panel of the chassis downward to ensure proper airflow and meet
safety requirements in the event of a fire.
•
•
When wall mounting EX2200-24P and EX2200-48P models, install the
wall-mount baffle above the units to reduce the risk of objects or
substances falling into the air exhaust or power supply, which could cause
a fire.
The holes in the mounting brackets are placed at 1 U (1.75 in. or 4.45 cm) apart so that
the switch can be mounted in any rack or cabinet that provides holes spaced at that
distance.
Related
Documentation
Mounting an EX2200 Switch on Two Posts of a Rack or Cabinet on page 81•
• Mounting an EX2200 Switch on Four Posts of a Rack or Cabinet on page 84
• Mounting an EX2200 Switch in a Recessed Position in a Rack or Cabinet on page 88
• Mounting an EX2200 Switch on a Desk or Other Level Surface on page 75
• Mounting an EX2200 Switch on a Wall on page 88
• Mounting an EX2200 Switch On or Under a Desk Using Screws on page 78
• Mounting an EX2200 Switch Using the Magnet Mount on page 94
• Connecting Earth Ground to an EX Series Switch on page 103
Mounting an EX2200 Switch on a Desk or Other Level Surface
You can mount an EX2200 switch on a desk or other level surface by using the four rubber
feet that are shipped with the switch. The rubber feet stabilize the chassis.
Before mounting the switch on a desk or other level surface:
•
Verify that the site meets the requirements described in “Site Preparation Checklist
for EX2200 Switches” on page 51.
75Copyright © 2011, Juniper Networks, Inc.
Chapter 8: Installing the Switch