Table 57: Alarm Condions on EX2300 Switches
(Connued)
Chassis
Component
Alarm Condion Alarm
Severity
Remedy
Management
Ethernet
interface
Management Ethernet
link is down.
Major (red)
• Check whether a cable is connected to the
management Ethernet interface, or whether the
cable is defecve. Replace the cable if required.
• If you are unable to resolve the problem, open a
support case using the Case Manager link at
hps://www.juniper.net/support/ or call
1-888-314-5822 (toll-free within the United States
and Canada) or 1-408-745-9500 (from outside the
United States).
Roung Engine /var paron usage is
high.
Minor
(yellow)
Clean up the system le storage space on the switch.
For more informaon, see Freeing Up System Storage
Space.
/var paron is full. Major (red) Clean up the system le storage space on the switch.
For more informaon, see Freeing Up System Storage
Space.
Rescue conguraon
is not set.
Minor
(yellow)
Use the request system configuration rescue save
command to set the rescue conguraon.
Feature usage requires
a license or the license
for the feature usage
has expired.
Minor
(yellow)
Install the required license for the feature specied in
the alarm. For more informaon, see Understanding
Soware Licenses for EX Series Switches.
SEE ALSO
Chassis Status LEDs in EX2300 Switches | 26
234