Installing and Connecng an EX2300 Switch | 104
EX2300 Site Guidelines and Requirements
IN THIS SECTION
Environmental Requirements and Specicaons for EX Series Switches | 55
General Site Guidelines | 62
Site Electrical Wiring Guidelines | 62
Rack Requirements | 63
Cabinet Requirements | 65
Requirements for Mounng an EX2300 Switch On or Under a Desk or Other Level Surface or On a
Wall | 66
Clearance Requirements for Airow and Hardware Maintenance for EX2300 Switches | 67
Environmental Requirements and Specicaons for EX Series Switches
The switch must be installed in a rack or cabinet housed in a dry, clean, well-venlated, and
temperature-controlled environment.
Ensure that these environmental guidelines are followed:
The site must be as dust-free as possible, because dust can clog air intake vents and lters, reducing
the eciency of the switch cooling system.
Maintain ambient airow for normal switch operaon. If the airow is blocked or restricted, or if the
intake air is too warm, the switch might overheat, leading to the switch temperature monitor shung
down the switch to protect the hardware components.
Table 19 on page 56 provides the required environmental condions for normal switch operaon.