Table 20: Site Electrical Wiring Guidelines
Site Wiring
Factor
Guidelines
Signaling
limitaons
If your site experiences any of the following problems, consult experts in electrical surge
suppression and shielding:
Improperly installed wires cause radio frequency interference (RFI).
Damage from lightning strikes occurs when wires exceed recommended distances or pass
between buildings.
Electromagnec pulses (EMPs) caused by lightning damage unshielded conductors and
electronic devices.
Radio
frequency
interference
To reduce or eliminate RFI from your site wiring, do the following:
Use a twisted-pair cable with a good distribuon of grounding conductors.
If you must exceed the recommended distances, use a high-quality twisted-pair cable with
one ground conductor for each data signal, when applicable.
Electromagnet
ic
compability
If your site is suscepble to problems with electromagnec compability (EMC), parcularly
from lightning or radio transmiers, seek expert advice.
Some of the problems caused by strong sources of electromagnec interference (EMI) are:
Destrucon of the signal drivers and receivers in the device
Electrical hazards as a result of power surges conducted over the lines into the equipment
Rack Requirements
You can mount the device on two-post racks or four-post racks.
Rack requirements consist of:
Rack type
Mounng bracket hole spacing
Rack size and strength
63

Table of Contents

Other manuals for Juniper EX2300 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper EX2300 Series and is the answer not in the manual?

Juniper EX2300 Series Specifications

General IconGeneral
SoftwareJunos OS
ModelEX2300
Ports24 or 48 10/100/1000BASE-T ports
Uplinks4 x 1GbE/10GbE SFP+/SFP uplinks
Power SupplyInternal or external power supply options
Rack Units1U
PoE/PoE+ PortsAvailable on some models (EX2300-C and EX2300)
Operating Temperature0° to 45°C
Input Voltage100 to 240 VAC
Layer 3 FeaturesRIP, OSPF, VRRP
Layer 2 FeaturesVLAN, STP, RSTP, MSTP, LACP
Security Features802.1X, DHCP snooping
ManagementCLI, Web UI, SNMP