Docu-No.: 0590020601-EN Rev. 1.6.0 Page 109
Appendix 5
LWF ASR Map 5.8
29/07
HCU REV.FULL AL.
• Receiver is still full after discharge.
• Receiver proximity switch too
sensitive adjusted or failed.
30
KLINK WRONG
KGR
• Protocol of KGR file does not match
that required by the installed com-
munication circuit card.
31 KLINK NO KGR • No KGR file loaded
32 HPORT FAIL • Host communication pcb error.
33 HPORT FAIL INIT • Host communication pcb could not
be initialized.
34
HPORT ILLEGAL
BD
• Improper pcb installed in the host
port location.
35 KPORT FAIL • K-Port has failed
36 KPORT FAIL INIT • K-Port communication pcb could not
be initialized.
37
KPORT ILLEGAL
BD
• Host communication pcb is installed
on the wrong port location-(K-Port).
38
KGR PARAM
ERROR
• One or more feeder parameters are
not correct for the specified feeder.
39 EXT IO FAIL • The MODBUS I-O connection has
failed.
40
EXT ALR
ACTIVATED
• Digital input on KCM selected for
External Alarm is active.
41 INTERLOCK
FAIL
• Drive pcb Run Enable digital input is
open during operation.
42 START
IGNORED
• Start conditions not fulfilled.
43 MASSFLOW
HIGH
• The current massflow is above the
tolerance entered in <ALARM>
menu parameter <MF ERR+>.
44 MASSFLOW
LOW
• The current massflow is below the
tolerance entered in <ALARM>
menu parameter <MF ERR->.
ASR(Alarm number) Description
Table page 4 of 6