Docu-No.: 0590020601-EN Rev. 1.6.0 Page 109
Appendix 5
LWF ASR Map 5.8
29/07
HCU REV.FULL AL.
Receiver is still full after discharge.
Receiver proximity switch too
sensitive adjusted or failed.
30
KLINK WRONG
KGR
Protocol of KGR file does not match
that required by the installed com-
munication circuit card.
31 KLINK NO KGR No KGR file loaded
32 HPORT FAIL Host communication pcb error.
33 HPORT FAIL INIT Host communication pcb could not
be initialized.
34
HPORT ILLEGAL
BD
Improper pcb installed in the host
port location.
35 KPORT FAIL K-Port has failed
36 KPORT FAIL INIT K-Port communication pcb could not
be initialized.
37
KPORT ILLEGAL
BD
Host communication pcb is installed
on the wrong port location-(K-Port).
38
KGR PARAM
ERROR
One or more feeder parameters are
not correct for the specified feeder.
39 EXT IO FAIL The MODBUS I-O connection has
failed.
40
EXT ALR
ACTIVATED
Digital input on KCM selected for
External Alarm is active.
41 INTERLOCK
FAIL
Drive pcb Run Enable digital input is
open during operation.
42 START
IGNORED
Start conditions not fulfilled.
43 MASSFLOW
HIGH
The current massflow is above the
tolerance entered in <ALARM>
menu parameter <MF ERR+>.
44 MASSFLOW
LOW
The current massflow is below the
tolerance entered in <ALARM>
menu parameter <MF ERR->.
ASR(Alarm number) Description
Table page 4 of 6

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the K-TRON K-Vision and is the answer not in the manual?

K-TRON K-Vision Specifications

General IconGeneral
BrandK-TRON
ModelK-Vision
CategoryControl Panel
LanguageEnglish

Related product manuals