EasyManuals Logo

K-TRON K-Vision User Manual

K-TRON K-Vision
121 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #32 background imageLoading...
Page #32 background image
1 Programming Reference
1.6 Scale menu
Page 32 Docu-No.: 0590020601-EN Rev. 1.6.0
SFT SELECTED
Node # Of Selected SFT
Selects the SFT to query parameters:
SFT #, SFT SN#, SFT ADDRESSED, SFT WEIGHT, SFT TYPE,
SFT STATUS.
Input range: 0 to 11
SFT ADDRESSED
SFT Addressed
Switching <Off> will address the selected SFT to <0>.
Switching <On> sets the SFT address selected in the SFT
SELECTED program parameter if there is an available spare SFT.
Input range: On or Off
SFT WEIGHT
SFT Weight
Displays the current gross weight on the selected SFT.
Input range: Display only
SFT TYPE
SFT Type
Displays the type of the selected SFT.
Input range: Display only
SFT STATUS
SFT Status
SFT error display. The <Process Status Word> of the selected SFT
is displayed. Any status word except 00000183 or 00000181 indicate
SFT failure. For mor informations see chapter 5.4.5.
Input range: Display only
SFT #
SFT Software
Display of the software version of the selected SFT.
Input range: Display only
HW #
Display of the hardware version of the selected SFT.
Input range: Display only
SFT SN #
SFT Serial # (Number)
Reports the serial number of the selected SFT.
SFT TEMPERATURE
SFT Temperature
Indicates the SFT’s internal temperature, in degrees Celsius, of the
selected SFT, if the SFT software supports this display parameter.
Parameter
Definition
Table page 2 of 2

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the K-TRON K-Vision and is the answer not in the manual?

K-TRON K-Vision Specifications

General IconGeneral
BrandK-TRON
ModelK-Vision
CategoryControl Panel
LanguageEnglish

Related product manuals