MULTICAL® 403
Kamstrup A/S · Technical description · FILE100000166_B_EN-55121689_M1_07.2023
Automatic
To be stated in order
Standard / Default
Offset of t1 and t2 (± 0.99K)
4
(See paragraph 7.3)
To be entered on the
basis of R
0
of the
sensor element as well
as the cable
resistance. If no
sensor data are
available, offset is set
at 0,00 K.
- -
t2 preset
Only active if meter type 4 is
selected.
-
0,01…185,00 °C + 250,00 °C 250,00 °C
t5 preset
Only relevant for meter types 1 and
2. (See paragraph 7.1.3)
-
0,01…185,00 °C 50,00 °C
DST
(Daylight Saving Time)
(See paragraph 7.10)
- Enabled / Disabled Depends on country code
1
Serial no. (Factory set unique serial number) is written on the meter, and cannot be changed after factory
programming.
2
If yearly target date 2 (MM.DD) and monthly target date (DD) are set at 00.00 and 00 respectively, these target
dates are disabled and the meter only uses yearly target date 1 and monthly target date 1.
3
θ
hc
= 250,00
°
C switches off the function. In all other meter types than 6,
θ
hc
is disabled and cannot be enabled after
delivery.
4
At submission of order you can choose ”fixed M-Bus address” which means that all meters included in the order will
be configured with the same primary M-Bus address.
5
R
0
is the resistance value of the sensor element in ohm (Ω) at 0 °C.

Table of Contents

Other manuals for Kamstrup MULTICAL 403

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kamstrup MULTICAL 403 and is the answer not in the manual?

Kamstrup MULTICAL 403 Specifications

General IconGeneral
TypeUltrasonic Heat Meter
Flow SensorUltrasonic
Pressure RatingPN16
Battery LifeUp to 16 years
ApprovalMID Class 2
DisplayLCD
CommunicationM-Bus, Wireless M-Bus, Modbus, BACnet
Power SupplyBattery
AccuracyClass 2
Protection ClassIP54
Housing MaterialComposite
Flow Rate Range0.6 m3/h to 15 m3/h