MULTICAL® 403
Kamstrup A/S · Technical description · FILE100000166_B_EN-55121689_M1_07.2023
13.3 High-resolution volume and energy
High-resolution volume and energy are available in the display and via serial communication. See below table.
Function
Application
Value
Resolution
Display
Standing start/stop
Volume
Energy
10 mL
1 Wh
Serially from latest integration
Standing start/stop
Volume
Energy
10 mL
1 Wh
Serially interpolated instantaneous
value with the meter’s time stamp
Flying start/stop
Volume
Energy
10 mL
1 Wh
Please contact Kamstrup A/S for further information
13.4 Temperature calibration
The temperature measurement is adjusted and calibrated during the production process and it does not require
further adjustment in the meter’s lifetime. The temperature circuit can only be adjusted in our factory.
13.5 Pulse interface
During test either optical reading head with USB plug (6699-099) for serial reading of high-resolution energy and
volume registers, or Pulse Interface (6699-143) with optical reading head and connection unit for high-resolution
pulse outputs is used. Do not forget that the meter must be in test mode.