MULTICAL® 403
Kamstrup A/S · Technical description · FILE100000166_B_EN-55121689_M1_07.2023
13.6 True energy calculation
During test and verification the heat meter’s energy calculation is compared to the ”true energy”, which is calculated
according to the formula of EN1434-1:2015 and OIML R75:2002.
The below-mentioned energy calculator can be supplied electronically by Kamstrup A/S.
The true energy at the most frequently used verification points is indicated in the table below:
t1 C]
t2 C]
∆Θ [K]
Inlet
[Wh/0,1 m
3
]
Outlet
[Wh/0,1 m
3
]
42
40
2
230,11
230,29
43
40
3
345,02
345,43
53
50
3
343,62
344,11
50
40
10
1146,70
1151,55
70
50
20
2272,03
2295,86
80
60
20
2261,08
2287,57
160
40
120
12793,12
13988,44
160
20
140
14900,00
16390,83

Table of Contents

Other manuals for Kamstrup MULTICAL 403

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kamstrup MULTICAL 403 and is the answer not in the manual?

Kamstrup MULTICAL 403 Specifications

General IconGeneral
TypeUltrasonic Heat Meter
Flow SensorUltrasonic
Pressure RatingPN16
Battery LifeUp to 16 years
ApprovalMID Class 2
DisplayLCD
CommunicationM-Bus, Wireless M-Bus, Modbus, BACnet
Power SupplyBattery
AccuracyClass 2
Protection ClassIP54
Housing MaterialComposite
Flow Rate Range0.6 m3/h to 15 m3/h

Related product manuals