It also appears from the table below that no matter how you exit ”SETUP loop when the meter is in operation, the
installation seal must be broken again and calculator top and base must be separated and reassembled if the
technician wants to regain access to ”SETUP loop”.
Transport state
In operation
1.
Primary key
Access to ”SETUP loop”
Access to ”SETUP loop”
locked
2.
Time out
Access to ”SETUP loop”
Access to ”SETUP loop”
locked
3.
”EndSetup”
Access to ”SETUP loop”
locked
Access to ”SETUP loop”
locked
6.3.1 Change of parameters in the ”SETUP loop
The user can navigate to the ”SETUP loop from the ”USER loop” by keeping the primary key activated for 9 seconds.
When the primary key is released, the ”SETUP loop” can be accessed, and after this the primary key is used for
navigating to the required parameter by activating the key at brief intervals. The ”SETUP loop” does not include
secondary readings, and, therefore, the index number always consists of 4 digits, see table with SETUP parameters.
In the ”SETUP loop”, the secondary key is used for accessing individual readings with the purpose of changing the
parameter in question. Pressing the secondary key, the first digit of the parameter in question (the digit farthest to
the left) starts flashing. The flashing digit can now be changed through brief activations of the secondary key. A brief
activation of the primary key moves focus to the next digit. Pressing the primary key when focus is on the last digit
(the digit farthest to the right), the meter saves the change and “OK” appears in the display.
Note: A change of the B-CCC code is not saved until you leave SETUP loop.
Depending on the meter’s configuration one or more menu points in ”SETUP loop” will be displayed as “Off”. This
means that the function is not available in the meter, i.e. the function has been disabled during factory
programming. If you try to access these readings via the secondary key, the frames around ”Off” are shown to
indicate that the function is not available in the meter.