EasyManuals Logo

Kamstrup MULTICAL 403 Technical Description

Kamstrup MULTICAL 403
145 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #45 background imageLoading...
Page #45 background image
MULTICAL® 403
Kamstrup A/S · Technical description · FILE100000166_B_EN-55121689_M1_07.2023
3.5 Target date
MULTICAL® 403 can be configured with up to two yearly target dates and two monthly target dates. These dates
determine on which date data is to be logged (saved) in the calculator’s interval logger. To avoid confusion about
which time of the day the calculator saves data, MULTICAL® 403 also, in addition to the date, includes a time stamp
for the logging. This time stamp is not included in this calculator’s predecessor, MULTICAL® 402, which simply
stamps data with a date. This difference also means that the date stamps of the two calculators vary in spite of the
fact that both calculators are configured with a target date, e.g. 01.01 [MM.DD]. Note that although the date stamps
of the two calculators are different, both calculators will in practice log (save) data at the same time. This is
illustrated by the following example:
MULTICAL® 402/602/801
MULTICAL® 303/403/603/803
Yearly target date
[MM.DD]
01.01
01.01
Monthly target date
[DD]
01
01
Date/time
[20YY.MM.DD/ hh.mm.ss]
2018.12.31 / 24.00.XX
1
2019.01.01 / 00.00.XX
1
Note that it is not possible to read out this time stamp from the calculator.
When using MULTICAL® 403 together with systems that are dependent on data being logged with a given target
date, it is important to select this date as target date in the calculator’s configuration. The target date can be
configured both via the calculator’s front keys in the SETUP loop” and via METERTOOL HCW, see paragraph 6.3 and
the technical description of METERTOOL HCW (5512-2097), respectively. If the target date is required to be set to
the last day of the month, the monthly target date [DD] is set to 31. MULTICAL® 403 automatically logs on the last
day of months with less than 31 days.
27
28
29
30
31
1
2
3
MULTICAL® 303/403/603/803
[MM.DD] [hh.mm.ss]
01.01 00.00.XX
01.01
MULTICAL® 402/602/801
[MM.DD] [hh.mm.ss]
12.31 24.00.XX

Table of Contents

Other manuals for Kamstrup MULTICAL 403

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kamstrup MULTICAL 403 and is the answer not in the manual?

Kamstrup MULTICAL 403 Specifications

General IconGeneral
TypeUltrasonic Heat Meter
Flow SensorUltrasonic
Pressure RatingPN16
Battery LifeUp to 16 years
ApprovalMID Class 2
DisplayLCD
CommunicationM-Bus, Wireless M-Bus, Modbus, BACnet
Power SupplyBattery
AccuracyClass 2
Protection ClassIP54
Housing MaterialComposite
Flow Rate Range0.6 m3/h to 15 m3/h

Related product manuals