MULTICAL® 403
Kamstrup A/S · Technical description · FILE100000166_B_EN-55121689_M1_07.2023
2.2 Electrical data
Calculator: E
c
(0,15 + 2/
) % Sensor set: E
t
(0,4 + 4/
) %
LCD – 7 or 8 digits, digit height 8,2 mm
9999,999 – 99999,99 – 999999,9 – 9999999
99999,999 – 999999,99 – 9999999,9 – 99999999
Programmable
Logging intervals: From one minute to one year
Logger content: All registers can be selected
Standard logger profile: 20 years, 36 months, 460 days, 72 hours
(with back-up battery)
Clock, calendar, leap year compensation, target date
Unadjusted by AMR: Less than 15 min./year from legal time
Adjusted by AMR every 48 hrs: Less than 7 sec. from legal time
Programmable under country code.
The function can be disabled so that ”technical normal time” is used
KMP protocol with CRC16 used for optical communication
as well as modules.
sensors
10
W RMS
3,65 VDC, 2 x A cells lithium
3,65 VDC, C-cell lithium
1
- Wall mounted
- Mounted on flow sensor
16 years @ t
BAT
< 30 °C
14 years @ t
BAT
< 40 °C
9 years @ t
BAT
< 30 °C
8 years @ t
BAT
< 40 °C
See paragraph 10.4 for further information.
(for real time clock)
Lifetime: 20 years @ t
BAT
< 40 °C with connected battery/supply or
4 years @ t
BAT
< 40 °C without connected battery/supply
230 VAC +15/-30 %, 50/60 Hz
24 VAC ±50 %, 50/60 Hz
Integral SuperCap eliminates interruptions due to short-term power failures
(Supply modules type 403-xxxxxxxxxxx7 and -8 only)
Fulfils EN 1434 class A and C (MID class E1 and E2)
1
For especially current-demanding applications, such as battery operation of an NB-IoT module. This battery package
includes a lithium C-cell as well as a special capacitor that helps the battery to deliver high pulse currents.