EasyManua.ls Logo

Kamstrup MULTICAL 403 - Examples of Information Codes

Kamstrup MULTICAL 403
145 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MULTICAL® 403
Kamstrup A/S · Technical description · FILE100000166_B_EN-55121689_M1_07.2023
Note: Info codes are configurable. Therefore, it is not certain that all above-mentioned parameters are available in a
given MULTICAL® 403. This depends on the selected country code.
7.7.2 Examples of information codes
Flashing ”INFO”
If the information code is different from
”00000000”, a flashing “INFO” will appear in the
meter’s display.
Current information code
The current info code can be displayed by
scrolling to the reading using the primary key on
the calculator front. When the current info code
is displayed ”INFO” stops flashing.
The current info code in the example indicates
that t1 is below measuring range or short-
circuited.
Info-event counter
If you activate the meter’s secondary key when
the info code is displayed you are informed how
many times the info code has been changed.
The value is increased every time the info code is
changed.
The info-event counter of a new meter will be 0
as transport state prevents counting during
transportation.
Info logger
If you activate the secondary key again, the info
code data logger is displayed.
The first display reading states the date of the
latest info code change.
The next activation of the secondary key displays
the info code from the above date. Repeated
activations of the secondary key alternately
induce dates and corresponding info codes.
The data logger saves 50 changes (all 50 changes
can be displayed).
Note: The info code is saved in the meter’s data logger too for diagnostic purposes.

Table of Contents

Other manuals for Kamstrup MULTICAL 403

Related product manuals