Motor data and controller adjustments of the asynchronous motor
© KEB, 2012-10 COMBIVERT F5-A, -E, -H Page 7.5 - 37
7
Figure 7.5.3.d Field weakening
dS.08 KP maximum voltage
dS.09 Ki maximum voltage
dS.04 KP maximum voltage
controller
dS.10 maximum voltage (max. -2% of
max. output voltage
imr_ref
Usd
Usq
1ms
-0.75
omega_1
= SQR (Usd
2
+
Usq
2
)
dr.18, dr.20, Imr
rated
+
-