EasyManuals Logo

KEB COMBIVERT F5-A User Manual

KEB COMBIVERT F5-A
552 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #475 background imageLoading...
Page #475 background image
CP-Parameterdenition
© KEB, 2012-10 COMBIVERT F5-A, -E, -H Page 7.16 - 9
7
7.16.5 Variable norm
Target of these parameters is to allocate a set of parameter addresses to the control. By this way arbitrary in-
verter parameters with self-specied standardizations are addressed.
Required parameters
The following conguration parameters must be available for one programmable parameter.
· Target address
· Characteristics
The following settings can be made in the characteristics:
bit 0-7: Target/source set with direct addressing
bit 8-11: Mode of set-addressing:
0: Target/source set of bit 0-7
1: Target/source set = current set
2: Target/source set = fr.9
3: Accept target/source setting from PP-Para telegram
4...15: free
Bit 12-13 Conversion mode
0: Standard
1: Invers
2: free
3: free
Bit 14 Multiplier / write variable
0: no
1: yes
Bit 15 Shifter / write variable
0: no
1: yes
Bit 16 Multiplier / reading variable
0: no
1: yes
Bit 17 Shifter / reading variable
0: no
1: yes
Bit 18 Offset variable
0: no
1: yes
Bit 19-20 Read/Write rights
0: Read/ Write
1: Read-Only

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KEB COMBIVERT F5-A and is the answer not in the manual?

KEB COMBIVERT F5-A Specifications

General IconGeneral
BrandKEB
ModelCOMBIVERT F5-A
CategoryControl Unit
LanguageEnglish

Related product manuals